Part of the process for registration of feeds containing enzymes by the CFIA is the provision by the applicant of an acceptable method of analysis of the enzyme in carrier/filler. The applicant is also required to provide the necessary data to support reliability of the method. The following protocol is intended to ensure that the method, data and test materials provided by the applicant are adequate to allow for expeditious evaluation, validation and approval of the methodology.
The purpose of the method submission is to allow the evaluator and analyst to understand and perform the method exactly as the originator intended. It is therefore necessary that the method contains all the necessary information presented in a detailed step by step standard operating procedure.
The method submitted must be clear and concisely written; currently in use by the submitting company; and proven to be specific, selective, reliable, and accurate for the active ingredient (in formulated products). The method must detail instructions for the preparation of a Standard Curve, and include detailed equations required to calculate activity (include Units). Critical control points and specifications for quality control and familiarization must be included in the methodology. In the event that the method in use requires highly specialized, expensive or automated equipment, an alternate manual and basic method should also be provided.
The following supporting documents for method performance standards must be included in the submission to properly
evaluate the method(s). (Please provide data in tabular form):
The applicant must provide the following information in support of the proposed methodology, performance standards, critical points, sample storage, stability etc.:
The applicant must provide information on the statistical confidence of the standard curve which is used (directly or indirectly) to measure enzyme activity.
Specify analytical range (maximum and minimum)
Provide three sets of standard curve calibration data and graphs (minimum 5 points). For each set, provide statistical data which supports reliability in the curve.
Provide a statistical comparison of the 3 standard curves.
Generally, a multi-point enzyme assay should be used for the determination of activity (i.e. a range of enzyme concentrations).
Provide a minimum of three (3) sets of enzyme assays graphs (minimum 5 points) for the determination of linearity, and analytical range. Specify the region of linearity.
Where a known enzyme standard is not available, provide statistical data in support of the use of an "in-house" standard. (i.e. provide previous assay results (with statistical comparison).
Provide analytical results from 3 batches (indicate lot number) of enzyme product (each tested in triplicate) for the determination of accuracy, precision, specificity, coefficient of variation, percent error.
Specify the percentage acceptable for the recovery of enzyme activity.
Indicate percent coefficient of variation of repeatability (within laboratory).
Indicate percent coefficient of variation of reproducibility (between laboratories) if possible.
Provide a description of the experimental design used by the company or other laboratory for the method evaluation(s). Include raw data and statistical analyses of method evaluation(s).
When the above requirements are met, CFIA laboratories will proceed with the laboratory testing of the method. For CFIA laboratories to test the method, the following materials must be supplied by the company.
The following criteria will be applied as a guide to the evaluation of methodology:
Upon request, the CFIA will prepare a report that includes the following information:
The CFIA must be informed of any modifications or new methodology. The new or modified methods must be verified. The degree of verification will depend on the changes.