These guidelines have been formulated jointly by Agriculture Canada, Fisheries and Oceans Canada and Health Canada. They represent important elements to be considered when carrying out a temperature distribution study1 for any product to be thermally processed in steam-still retorts excluding crateless retorts.
When appropriate, temperature distribution studies will be evaluated by these departments using the elements given in these guidelines. Only persons experienced and knowledgeable on thermal processing in steam-still retorts should carry out and evaluate the results of such studies.
1 Adapted from Temperature Distribution Protocol for Processing in Steam-Still Retorts, from the Institute for Thermal Processing Specialists, P.O. Box 2764, Fairfax, Virginia, U.S.A. 22301-0764, (703) 591-1108.
Temperature distribution studies should be done to: develop or validate a venting schedule; to locate cold or slow heating zones in preparation for heat-penetration studies; in the case of new installations; and for any changes to an installation which may influence the temperature distribution in the product zone. Examples are: changes to steam spreaders, decreased steam pressure in lines, changes to the product loading patterns, changes to the basket and/or dividers, etc.
Prior to the selection of the test retort(s) a survey should be made of the following:
A detailed diagram identifying all equipment for which the use of steam is required (including the numbering system used to identify each retort) and the steam supply line arrangement should be made as prescribed in this section. (Note that it is recommended that all steam lines from the main line to the retort(s) be clearly identified in the diagram from those steam lines feeding other equipment).
3.2.1 Boiler(s) Capacity (psi or kPa)
Record potential and actual settings, amount of steam developed and available, i.e., pounds or kilograms of steam produced per unit time.
3.2.2 Retort Header Pressure
It is important to insure that adequate steam pressure and volume is being delivered to the retort(s). This measurement should be taken when maximum operational demand is made on the steam supply.
3.2.3 Headers, Manifolds, Lines and Valves
Record pipe size and length, valve size and types, of the main steam line from the boiler(s) immediately before the pressure/steam regulator to the retort(s).
3.2.4 All Connecting Steam Lines Other than to the Retort
Record size of all connecting steam lines to the main steam line noting other equipment using steam (e.g., blanchers, exhaust boxes, etc.).
A detailed diagram of each retort, including associated operational equipment as identified below, should be made. Where identical retort configurations exist, one diagram is sufficient. The designated retort number(s) must be shown on the diagram. The system should include the full manifold system.
3.3.1 Retort shell
Record retort type and internal dimensions. For vertical retorts, note the presence of centring guides and/or baffle plates.
3.3.1 Retort Crates
Record maximum number of crates used in each run as well as their design and dimensions.
3.3.3 Steam Supply from Pressure/Steam Regulator to Retort
Record pipe sizes, valve type and sizes, pressure/steam regulators or reducers and all pipe fittings including steam by-pass lines and steam spreaders (shape, pipe size, length, location; number, size and location of holes in pipe).
3.3.4 Steam Control
Record type of controller (i.e., pressure to air, temperature to air) and location of sensor.
3.3.5 Air System for Controls (if applicable)
Record size of air compressors, air dryer capacity, filter type and location(s). Include the line pressure that must be maintained for operation of the controls and how this pressure is controlled.
3.3.6 Other Piping and Required Equipment
Record the following information:
3.3.7 Recording Device
Note type of recording device (recorder or recorder/controller). For more information consult section 7.6.2.2 of the Recommended Canadian Code of Hygienic Practice for Low-acid and Acidified Low-Acid Foods in Hermetically Sealed Containers (Canned Foods).
Record the following information:
Note: It is important to document the survey findings correctly in order to enable a proper evaluation before selecting the test retort(s). The documented survey should be maintained on company's file and updated when necessary.
All information required in section 3 above must be taken into consideration when selecting the test retort(s). The retort(s) selected should represent the worst possible condition that could influence the delivery of the venting procedure. Note that under certain conditions (i.e., when the plumbing and equipment configuration is not identical for all retorts), it may be necessary to carry out a temperature-distribution study of a number of retorts in a system in order to determine which one represents the worst case.
Where all plumbing and equipment configurations are identical, it is generally advisable to select as the worst possible case the retort which is located at the end of the steam line. However, this is not always the case. This is an area where the knowledge and experience of the specialist supervising the study are of upmost importance.
Note if data logger has a sufficient number of channels to monitor adequately and record temperatures during the temperature-distribution study.
Note if thermocouples and lead wires, or other temperature-measuring devices used are of an appropriate type, size, length and number to adequately monitor the temperatures within the retort.
Note which type used (Mercury-in-glass thermometer or other) see 3.3.6 item 8.
Note which type used (if required) see 3.3.6 item 9.
Note if diameter is sufficient to accommodate number of lead wires (if thermocouples are used as the temperature measuring device) and specify its location on the retort.
The MIG shall conform with section 7.6.2.1 of the Recommended Canadian Code of Hygienic Practice for Low-acid and Acidified Low-Acid Foods in Hermetically Sealed Containers (Canned Foods). Prior to performing a temperature-distribution test, the MIG thermometer (or equivalent) shall be certified by a recognized authority as meeting the stated accuracy according to specifications, such as set out by the National Research Council of Canada (NRC), and calibrated. If it has been calibrated and certified in the past 12 months, then it should not have to be done again unless there is doubt as to its accuracy.
2 For more information consult the "Standard Guide for Use in the Establishment of Thermal Processes for Foods Packaged in Flexible Containers" ASTM F 1168-88, 1988.
A minimum of 12 TMDs (or equivalent) should be used. However, the number of TMDs depends upon many factors, for example, size of the retort chamber zone, container size, number and configuration in the baskets, etc.
TMDs shall be placed in the following locations in the retort vessel:
As a general guidance it is recommended to place TMDs in the following manner:
3a. For Vertical Retorts:
Temperatures should be measured in the middle of each basket at the top, centre and bottom. If more thermocouples are available, points along the edge at the top and bottom of each basket may be measured. If still more thermocouples are available, other points around the periphery of the basket may be measured.
3b. For Horizontal3 Retorts:
In this type of retort the product is usually in cars. In a horizontal retort thermocouples should be located in the middle of the basket at the top, centre and bottom of each car. If more thermocouples are available, they should be located at the centre of the outside of the four sides of the car.
3 Procedures for carrying out a heat penetration test and analysis of the resulting. Prepared by Irving Pflug, University of Minnesota, 1975. Published by Department of Food Science and Nutrition, University of Minnesota, 100 Union Street, Minneapolis, MN 55455.
Note: A schematic diagram of the placement of all TMDs within the retort and covering all three dimensions should become part of information recorded for the temperature-distribution tests.
4. For determining the initial temperature (IT), TMDs should be placed in a sufficient number of medium-filled testing containers. Generally two containers have been found to be acceptable. Alternatively, a hand-held thermometer may also be used to make that determination. Ideally all containers in the retort should be equilibrated to a previously identified IT.
The initial temperature is usually determined from the container having the lowest temperature. When determining the test IT, the range of initial temperatures to be encountered during normal commercial operation should be taken into account and the coldest IT be selected.
The following are critical and should be monitored and recorded during the test.
In addition, the following points are important and are highly recommended to be monitored and recorded during the test.
For more information on vents and venting system refer to sections 7.6.3.1.7. and 7.6.3.1.8 of the Recommended Canadian Code of Hygienic Practice for Low-acid and Acidified Low-acid Foods in Hermetically Sealed Containers (Canned Foods).
Next page: Chapter 13 Subject 3 | Previous page: Chapter 13 Subject 1