The next review date for this manual is anticipated for September 8, 2011.
For further information or clarification, please contact the CFIA Forestry Division.
Amendments to this procedure will be given a consecutive number and will be
dated.
Please ensure that all amendments are inserted, obsolete pages removed, and
the record below is completed.
Amendment No.
Amended by
Date of submission for approval of
amendment
Summary of amendment and number of amended
page(s)
1
Mireille Marcotte
May 13, 2008
housekeeping (throughout)
2
Brad Doiron
September 8, 2009
housekeeping re: glossary of terms and removal of references to the former
program (throughout); Added Service Provider's responsibilities when a
facility changing owner or management retains the facility registration
(CA) number (sections 7.1
and 7.7.2); Clarified facility's suspension process (sections 7.3b(v),
7.4(1) and 7.4(4)); Deleting duplicate information in section 7.6
The CFIA Quality
System Requirements for Service Providers approved under the CWPCP is a
supplementary document to the Service Contract for the CFIA Policy D-01-05, Canadian
Wood Packaging Certification Program (CWPCP). For the purpose of this document,
a Service Provider is an organization, company or person who has entered into a
Service Contract with CFIA for the CWPCP and is
accountable to the CFIA for the activities
outlined herein. The Service Contract is a contract signed between the CFIA and a Service Provider
for the delivery of registration and evaluation audits and follow-up activities
at facilities registered under the CWPCP (i.e. that have applied and have been approved by
the CFIA to
participate in the CWPCP).
This document identifies the functional requirements that must be met by a
Service Provider authorized to provide inspection services for the CWPCP. The
Service Provider's policies and procedures that address these requirements
must be described in a Quality Management System Manual (herein referred to as
the manual) that will be subject to approval by the CFIA and to review from time
to time.
This document is intended for use by authorized Service Providers involved
in the inspection of wood packaging heat treatment facilities and/or wood
packaging manufacturers under the CWPCP, CFIA inspection staff and any
other interested parties. Within this document, the term facility refers to
either a wood packaging facility, a fumigation facility or an HT treatment facility. A treatment facility is
an officially authorized facility where recognized phytosanitary wood
treatments are performed (i.e., within the
content of this directive examples include: KD-HT,
HT, methyl bromide fumigation,
Chemical Pressure Impregnation).
An organization, company or person (referred to as the
"applicant") who wish to be recognized as Service Provider must agree
to comply with the terms and conditions set out under the CFIA Service Contract
developed under the Canadian Wood Packaging Certification Program (CWPCP)
(Policy Directive D-01-05).
An application for recognition as Service Provider pursuant to the standards
shall be made in accordance to the Request for Proposal issued by CFIA. The application shall
include a clear statement as to the scope of the recognition requested and such
documents, including operating procedures, personnel proficiency assessment
process and internal audit reports, (as outlined in the Request for Proposal)
that will enable CFIA to determine if the
requirements of this standard have been met.
The CFIA shall
review the application referred to in 5.1 against the requirements established
by this standard and the Request for Proposal, shall prepare a record of
evaluation indicating the extent of fulfilment of the requirements and shall
notify the applicant. Where this "desk audit" indicates essential
fulfilment of the requirements of the standards, an initial systems audit (an
audit conducted by the CFIA on the Service Provider
and a representative number of registered facilities to verify compliance to
the terms and conditions of the recognition) will be recommended.
Where the CFIA
confirms that the requirements set out in the standards have been fulfilled the
CFIA may recommend
to the President of the CFIA that the Service
Provider be formally recognized as competent to perform specific activities by
entering into an agreement pursuant to subsection 14(1) of the Canadian
Food Inspection Agency Act to accept specific recommendations from the
Service Provider. The CFIA shall make public this
decision and agreement.
be capable of conducting work on a national basis
within Canada in both official languages;
be responsible for its verification
activities;
have documented policies and decision-making
procedures that distinguish between activities for which it has received formal
recognition and any other activities in which the body is engaged;
not offer consultancies or other services which
may compromise the objectivity of its recognition process and decisions;
be soundly supported financially;
be free from commercial or any other influence
that might affect its integrity;
ensure sufficient and competent personnel to
undertake the requirements of audit program;
maintain a Manual approved by the CFIA governing all aspects of
the inspection program;
in cooperation with CFIA provide to registered
facilities, inspection requirements, recommend improvements to the requirements
or process as experience or external conditions indicate, and notify certified
facilities of updates or changes to the regulations as directed by the CFIA.
The Service Provider shall perform the following tasks:
Receive applications from facilities wishing to be
registered under the CWPCP, review
the facility's Manual and recommend participation to the CFIA.
Monitor compliance with the registration
requirements through a regular program of audits, at the frequency and in the
format specified by the CFIA.
Identify, report to the facility and monitor the
resolution of minor non-conformances.
Identify, report to the facility and the CFIA any major
non-conformances and inspect as directed to confirm their resolution.
Maintain a manual approved by CFIA covering all aspects of
the auditing program including provisions set out in this guideline.
Maintain records and report to the CFIA in the manner and
frequency specified.
Respond to applications by providing appropriate
documentation, guidelines and references.
Provide guidelines for the preparation of a
facility manual.
Describe procedures to process and evaluate
applications and manuals, including initial audits and checklists.
Attend joint audits of facilities with CFIA.
Maintain knowledge of CFIA policies and guidelines,
as well as CFIA's export
requirements pertaining to wood exports.
Inform the registered facility of any changes
within this program.
Describe procedure for signing up new facility to
Inspection Services Agreement.
Describe procedure for conducting inspections
(provide examples of checklists and reports) and reporting results (this may
all be described in a separate inspection manual).
Upon execution of a Service Contract, the Service
Provider will make its services as a Service Provider under the CWPCP available
to facilities wishing to register under such program.
The Service Provider will conduct the reviews,
inspections, audits and other duties set out under the CWPCP program
and detailed in the manual.
Upon receipt of the required application form, the
manual, and Information Collection Acknowledgment (Appendix 1 of this
Agreement) from a facility applying for registration, and upon receiving from
the facility a signed agreement for Service Provider services, in a form
satisfactory to the Service Provider, the Service Provider shall:
Forward to the CFIA a copy of the
facility's complete application;
review and report on the facility's manual against the conditions
specified in the D-01-05 (CWPCP) section
4.3 (quality requirements);
prepare a report of its assessment for the CFIA, including its
recommendation as to acceptance or rejection of the application, and the
reasons therefore; and
recommend for registration to the CFIA.
For facilities accepted in principle for
registration by the CFIA, the CFIA and the Service Provider
will coordinate and conduct a joint initial evaluation audit of the facility to
verify that it can meet the requirements specified in the CWPCP. An
evaluation audit is an audit performed at the time of registration to verify
that a facility is capable of meeting the standards prescribed. The audit also
verifies that the facility manual is being adhered to and that facility
employees are sufficiently trained.
Note: If a new application is sent because the facility is
changing ownership and the new owner wishes to retain the facility's
CA number, it is the
responsibility of the Service Provider to inform the facility of all the
implications and responsibilities associated with retaining this registration
number.
Audits are to be conducted in accordance with the Service Agreement and as
outlined in this section.
Audits by Service Provider
The Service Provider will attend at each
registered facility contracting with it as a Service Provider and audit the
facility's operations in the context of the facility's manual, and as
against the applicable requirements of the CWPCP.
The Service Provider will conduct all audits in a
manner that is consistent with the requirements set out in this document, and
set out in "The Quality System Requirements the Canadian Wood
Packaging Certification Program (CWPCP) or the Canadian Heat Treated Wood
Products Certification Program (CHTWPCP)" QSM no. 02,
and without any prejudice or conflict of interest.
Subject to reporting to the CFIA as required under the
Service Contract and the CWPCP, the
Service Provider will ensure that all records of inspections, audits,
enforcement actions taken and any other information pertaining to facilities
are kept confidential and secure at all times.
Audits conducted by CFIA
The CFIA will
conduct an audit on the Service Provider and a representative sample of the
registered facilities to verify compliance to the terms and conditions of this
recognition.
7.2.2 Activities and Frequency of Audits
Facility with a Heat Treatment
Chamber (Primary Treatment Facility)
Application for registration under the
CWPCP
& Submission of the Manual
Prior to registration.
Prior to registration.
Issuance of facility registration number
by CFIA
Upon approval of facility's manual.
Upon approval of facility's manual.
Evaluation Audit conducted by Service
Provider in cooperation with the CFIA
To be conducted prior to registration, or as a result of
suspension from the program to confirm that a facility has adequately addressed
the non-conformities and initiated quality activities that would ensure that
future non-conformities may be avoided. Often when evaluation audits are
performed following suspension significant revision of the manual has been
completed.
To be conducted prior to registration, or as a result of
suspension from the program to confirm that a facility has adequately addressed
the non-conformities and initiated quality activities that would ensure that
future non-conformities may be avoided. Often when evaluation audits are
performed following suspension significant revision of the manual has been
completed.
Verification Audit conducted by the
Service Provider (i.e., a review of the
organizational structure, procedures, processes and resources used by a
registered facility in implementing the certification program)
A minimum of 4/year.
A minimum of 4/year in the first year of registration or
re-registration following suspension and 2/year in subsequent years.
Follow-up audit (i.e., an audit performed to verify that
corrective actions ordered have been completed and that facility operations
continue to meet the specifications of the facility manual)
At any time until non-conformances are corrected to the
satisfaction of the Service Provider and/or CFIA.
At any time until non-conformances are corrected to the
satisfaction of the Service Provider and/or CFIA.
Systems Audits conducted by CFIA
An annual audit conducted on the Service Provider and a
representative sample (up to 33%) of registered facilities on an annual
basis.
An audit annual audit conducted on the Service Provider
and a representative sample (up to 33%) of registered facilities on an annual
basis.
The Service Provider will provide a report to the facility of its audit and
will identifying elements that require improvement, non-conformances, and
corrective actions which are required in the event that non-conformance has
been identified.
In the event that corrective actions are required to address
non-conformances which has been identified during the audit, the Service
Provider will take the following additional actions:
for a minor non-conformance, as outlined under the
Quality System Guidelines for Facility Registration under the Wood Product
Certification Programs (CHTWPCP
and CWPCP)(QSM 02), the Service Provider shall:
provide a report to the facility of its audit
within 5 working days after having conducted the audit;
verify that the corrective actions requested has been completed by the
facility within a reasonable time frame, not exceeding one (1) month from the
date of initial notification of the non-conformance by the Service
Provider;
provide the CFIA
in its quarterly report information regarding the non-conformance, the planned
corrective action and follow-up confirmation that the corrective action has
been completed.
for a major non-conformance, as defined under the
Quality System Guidelines for Facility Registration under the Wood Product
Certification Programs (CHTWPCP
and CWPCP), the
Service Provider shall:
deliver to the registered facility, and to the
CFIA a notice in
writing with a description of the non-conformance and the required corrective
action within 3 working days of such non-conformance;
request the facility to take corrective action within a time frame
appropriate to address the non-conformance but not to exceed 10 working
days;
follow-up on corrective actions taken by the facility as often as required
to verify full compliance within 10 working days of initial notification of the
corrective action due date;
provide written confirmation to the CFIA, that the required
corrective action, or other actions, has not been taken within 3 working
days;
where the major non-conformance compromises the integrity of the program,
the Service Provider will recommend, to the CFIA, the suspension of the
facility from the program and will remove, in collaboration with the CFIA, all stamps and
certificates relevant to this program. The recommendation to suspend a facility
will occur within 3 working days following the audit of the facility by the
Service Provider.
Where the CFIA has been notified of a
major non-conformance as set out herein, the CFIA may apply an interim
suspension of the facility's registration under the CWPCP, and will
provide notice thereof to the facility and the Service Provider immediately
upon the decision to suspend by the CFIA. During the suspension
period, the registered facility will not be permitted to certify wood packaging
products for export as outlined in the CWPCP.
Should the CFIA determine in its sole
and unfettered discretion that the proposed corrective action or implemented
corrective action by the Service Provider is unsatisfactory, the Parties agree
that the CFIA
reserves the right to directly impose or implement upon the registered facility
whatever corrective action it deems necessary to correct the
non-conformance.
In the event of a non-conformance by a registered
facility, the CFIA
may increase the frequency of inspection of the facility, until corrective
actions satisfactory to the CFIA are verified by the
Service Provider as being complete.
Where the CFIA determines, in its sole
and unfettered discretion, that a registered facility is consistently unable to
maintain conformance with the CWPCP or that a
registered facility's non-conformance jeopardizes the integrity of the
CWPCP,
the CFIA may suspend
or revoke the registered facility's registration under the CWPCP. In such
event, the CFIA
program officer will notify the Service Provider and the registered facility in
writing of this action.
If the facility's corrective actions and
quality are deemed sufficient by the CFIA, the CFIA will lift the suspension
will assign the facility a new inspection frequency. Once the facility has
demonstrated to the Service Provider on-going compliance with the requirements
of the CWPCP, the
Service Provider will reduce the frequency of inspection to that specified the
Quality System Procedures for The Export Certification Programs, CHTWPCP
(D-03-02) and the CWPCP
(D-01-05).
The Service Provider must describe procedures for conducting inspections
(provide examples of checklists and reports) and reporting results (this may
all be described in a separate inspection manual). The Service Provider must
describe procedures for reporting non-conformity and, if major, notifying the
CFIA and must
describe procedures for following up major non-conformity and reporting to the
CFIA.
In the evaluation and surveillance audit the following information must be
included:
Type of audit (Evaluation, or Verification audit):
Date of Audit:
Date of Previous Audit:
Audit Report No.:
Facility Name:
Address:
Location:
Lead Auditor:
Team Members:
Summary of Audit
List of minor non-conformances
Corrective Action Requests
List of major non-conformances
Corrective Action Requests
Facility Compliance status: Compliant Suspended
Signature of lead Auditor:
Date:
Signature of Facility Representative:
Date:
The Service Provider will provide to the CFIA annually, on or before
March 31 of each year, a detailed report in writing of all audits, inspections
and follow-up activities completed during that fiscal year. The report will
include, but will not be limited to, a listing of facilities by Service
Providers, information on the total number of audits performed by each Service
Provider, a list of the facilities audited, a list of major non-conformances
found, number of facilities added or deleted from the program and relevant
dates.
The Service Provider will advise the CFIA in writing as soon as it
comes to the attention of the Service Provider that a registered facility
ceases to operate under agreement with the Service Provider or has withdrawn
from the CWPCP.
The Service Provider will maintain for a period of
at least two (2) years all records pertaining to its verification of
facilities, including but not limited to: assessment reports for registration,
audit reports, reports of non-conformances and follow-up audits, authorizations
of changes to manuals and to the training of Service Provider staff.
The Service Provider will complete and date a
report of each audit conducted on the registered facilities they have audited
in the process, and such reports will be kept on file by the Service Provider
for periodic review by the CFIA.
The Service Provider will meet any other reporting
requirements as mutually agreed upon from time to time.
A Registered Facility will be suspended, in full or in part, for a specified
period if:
an audit identifies a system failure that casts doubt on the ability of the
facility to adequately discharge its duties;
agreed corrective actions are not implemented within the prescribed time
period;
applicable fees are not paid.
7.7.2 Cancellation
A Registered Facility will be cancelled, in full or in part, if:
requested by the facility; or
an audit identifies systematic, ongoing failure of the facility to
adequately discharge its duties.
If a registered facility is permanently removed from the program, resold or
operating under new managements and also operating under a new Certificate of
Registration and Registration Number or voluntarily withdraws from the CWPCP, their
facility number shall be cancelled from use and removed from the CFIA list of registered wood
packaging facilities or the CFIA list of registered wood
packaging treatment facilities. The facility registration number must not be
re-used.
Note: If a registered facility is resold or operating under new management
but not operating under a new Certificate of Registration and Registration
Number (the new owner or manager wishes to retain the facility's CA number), it is the responsibility
of the Service Provider to inform the facility of all the implications and
responsibilities associated with retaining this registration number.
The CFIA Auditor
or Service provider forwards an e-mail to the Area Forestry Network Specialist
and the Forestry Assistant advising that the facility has been cancelled from
the CWPCP. The
CFIA will send a
letter to the facility providing officially notification that the facility has
been cancelled from the program.
The CFIA will
arrange for the cancelled facility registration number to be removed from the
CFIA Forestry
Website.
7.7.3 Reinstating of Facility Registration
Wood packaging facilities or treatment facility that have been cancelled
from the CWPCP must
completely re-register starting with submission of the CWPCP
application form.
Where the CFIA determines in its sole
and unfettered discretion that the Service Provider has not complied with the
requirements of the CWPCP or is in
default of any representation, covenant, term or condition of the articles of
Agreement, the CFIA
will provide the Service Provider with a report detailing such non-compliance
and/or default.
Upon receipt of such report, the Service Provider
will immediately begin remedying such non-compliance and/or default and will
demonstrate to the CFIA within one (1) month
that such non-compliance and/or default has been remedied to the satisfaction
of the CFIA, failing
which, the CFIA will
be entitled to suspend or revoke, at its sole discretion, recognition of the
Service Provider as a Service Provider under the CWPCP and to
communicate the same to the registered facilities contracting with the Service
Provider.
The CFIA may, in its sole and
unfettered discretion, increase the frequency of inspections of the Service
Provider where non-compliance or defaults exist as described in this
section.
Facilities recommended for registration to the
CFIA by a Service
Provider and registered by CFIA and which has been
subsequently cancelled from the program, will be required to seek the service
of another CFIA
recognized Service Provider.
Fees payable by facilities for participation under this program, will be
made directly to the CFIA. The CFIA will be charging fees in
accordance with the Canadian Food Inspection Agency Fees Notice.
Individuals requiring more information on fee schedules may contact any CFIA regional office.
Note: At time of publication of this document, the annual CFIA registration fee for
facilities participating under this program is $400.00. The CFIA reserves the right to
charge an additional fee for its service, in accordance with the Canadian
Food Inspection Agency Fees Notice, for follow-up inspection activities
performed to verify that the requested corrective actions have been taken by
the facilities, to address the major non-conformances.
I (name
of owner or person with possession, care, or control of the facility),
hereby acknowledge that I have read and understand the following terms and
conditions as they apply to the collection of information related to the
facility located at (address).
The Canadian Wood Packaging Certification Program
1. I have been informed and understand that:
The Canadian Food Inspection Agency (CFIA) has
recognized (full legal name of the Service Provider)
as a Service Provider under the Canadian Wood Packaging Certification Program
(CWPCP) established in Policy Directive D-01-05.
The (full legal name of the Service Provider)
is responsible for collecting, reviewing and reporting to the CFIA on the facility's
Application for Registration to the Canadian Wood Packaging Certification
Program (CWPCP) and manual.
The CFIA is responsible for the
registration, suspension or cancellation of registration of any facility
registered in the CWPCP.
Legal Ownership/Possession/Care or Control
2. (1) I hereby confirm that I am the owner, or person with legal
possession, care, or
control of the facility in question and that I have the full and complete
right to grant permission to (full legal name of the Service Provider)
to disclose to the CFIA the following
information and documents:
name of the facility;
address of the facility;
telephone number of the facility;
the facility's Application for Registration to the Canadian Wood
Packaging Certification Program (CWPCP); and
the facility's manual.
and furthermore I grant permission to (full legal name of the Service
Provider) to disclose said information and materials.
(2) I further confirm that I have the right and authority to grant and
provide such permission to disclose the information and documents as described
in subparagraph 2(1) without the consent of any third Party and without
violating the rights of any third Party.
I hereby confirm the truth of the above statements and that I have read and
understand accept and agree with the above statements and terms.