The next review date for this manual is anticipated for March 3, 2012. For further information or clarification, please
contact the Forestry Bureau, Canadian Food Inspection Agency (CFIA).
The CFIA Quality System Requirements for Service Providers is
a supplementary document to the Service Agreement signed under the provisions of the CFIA Directive D-03-02, Canadian Heat Treated Wood Products Certification
Program for Export (CHTWPCP). For the purposes of this document, a Service Provider is an organization, company or person
who is accountable to the CFIA for the delivery of the CHTWPCP, providing reports of all audits,
inspections, incidents of non-conformance, and follow-up activities such as re-inspection of non-compliant facilities.
This document identifies the functional requirements that must be met by a Service Provider authorized to provide
inspection services under CHTWPCP. The
Service Provider's policies and procedures that address these requirements must be described in a Quality Management
System Manual (herein referred to as Manual) that will be subject to approval by the CFIA and to review from time to time. For the purposes of this document, a
Manual is a facility's detailed operational manual which specifies measures to be used to meet prescribed standards,
i.e., all requirements pertaining to the wood product certification program which are
referred to in Directive D-03-02, Canadian Heat Treated Wood
Products Certification Program (CHTWPCP), the CFIA QSM-02, the PI-07, and this
document.
This document is intended for use by authorized Service Providers involved in the inspection of heat treatment facilities
(within the content of this directive examples include: kiln dried-heat treatment, heat treatment) and/or wood packaging
manufacturers, CFIA inspection staff and any other authorized
parties. CLSAB accredited grading agencies which
are recognized by the CFIA as Service Providers are not subject
to the provisions outlined within this document. The requirements for these agencies will be outlined in the QSM-05, Quality System
Requirements for CLSAB and CLSAB Accredited Agencies Approved under the CHTWPCP.
CFIA QSM-02, Quality System Requirements For Facility Registration under the Canadian
Wood Packaging Certification Program (CWPCP) or the Canadian Heat Treated Wood Products Certification Program (CHTWPCP)
CFIA PI-07, The Technical Heat
Treatment Guidelines and Operating Conditions Manual
Parties wishing to be recognized as Services Providers must agree to comply with the terms and conditions set under the
provisions of the CFIA Directive D-03-02, Canadian Heat Treated
Wood Products Certification Program for Export (CHTWPCP).
An application for recognition as Service Provider pursuant to the standards shall be submitted to the CFIA The applicant shall include a clear statement as to the scope of the
recognition requested, including a Quality Manual which will outline the elements identified within this document.
The CFIA shall review the application and the Manual referred
to in 5.1, against the requirements established by this standard, and shall prepare a record of evaluation indicating the
extent of fulfilment of the requirements and shall notify the applicant. Where this evaluation indicates essential
fulfilment of the requirements of the standards, an initial systems audit will be conducted. A system audit is an audit
conducted by the CFIA on the Service Provider and a
representative number of registered facilities (facilities that has applied and has been approved by the CFIA to participate in the CHTWPCP) to verify compliance to the
terms and conditions of the recognition.
The CFIA shall formally recognize the applicant as Service
Providers under the CHTWPCP, once it
has determined that the requirements set out in the standards have been fulfilled. The CFIA shall make public this decision by posting the applicant's name
as a Service Provider for the purpose of the CHTWPCP on the CFIA website.
be capable of conducting work on a national basis within Canada in both official
languages;
be responsible for its verification activities;
have documented policies and decision-making procedures that distinguish between activities for
which it has received formal recognition and any other activities in which the body is engaged;
not offer consultancies or other services which may compromise the objectivity of its
recognition process and decisions;
be soundly supported financially;
be free from commercial or any other influence that might affect its integrity;
ensure sufficient and competent personnel to undertake the requirements of audit program;
maintain a Quality Plan approved by the CFIA governing all aspects of the inspection program;
in cooperation with CFIA provide to
registered facilities, inspection requirements, recommend improvements to the requirements or process as experience or
external conditions indicate, and notify certified facilities of updates or changes to the regulations as directed by the
CFIA.
The Service Provider will make its services as a Service Provider under the CHTWPCP available to facilities wishing to
register under such program.
The Service Provider will conduct the reviews, audits and other duties set out under the
CHTWPCP program and detailed in the
Manual.
Upon receipt of the required application form, the Manual, and Information Collection
Acknowledgment (Appendix 1) from a facility applying for registration, and upon receiving from the facility a signed
agreement for Service Provider services, in a form satisfactory to the Service Provider, the Service Provider will:
forward to the CFIA a copy of the
facility's complete application;
review and report on the facility's Manual against the conditions specified in the CHTWPCP;
Submit, the facility's application along with the endorsed Manual to the CFIA, for review and approval;
recommend for registration to the CFIA.
For facilities approved for registration by the CFIA, the Service Provider will conduct a an initial evaluation audit of
the facility, in consultation with the CFIA, to verify that it
meets the requirements specified in the CHTWPCP. An evaluation audit is an audit
performed at the time of registration to verify that a facility is capable of meeting the standards prescribed. The audit
also verifies that the facility Manual is being adhered to and that facility employees are sufficiently trained.
Audits are to be conducted in accordance with the program as outlined in this section.
Audits conducted by Service Provider:
The Service Provider will audit the facility's operations against the applicable
requirements of the CHTWPCP and the
facility's Manual.
The Service Provider will conduct all audits in a manner that is consistent with the
requirements set out in this document, and in the QSM-02, Quality System
Requirements For Facility Registration under the Canadian Wood Packaging Certification Program (CWPCP) or the Canadian Heat
Treated Wood Products Certification Program (CHTWPCP), and without any prejudice or conflict of interest.
Subject to reporting to the CFIA as
required under the CHTWPCP, the Service
Provider will ensure that all records of audits, enforcement actions taken and any other information pertaining to
facilities are kept confidential and secured at all times.
Audits conducted by CFIA:
The CFIA will conduct an audit on the Service Provider and a
representative sample of the registered facilities to verify compliance to the terms and conditions of this recognition.
7.2.2 Activities and Frequency of Audits
Facility with a Heat Treatment Chamber (Primary Treatment Facility)
Application for registration under the CHTWPCP, CWPCP & Submission of the Manual
For existing participants in the Canadian Lumber Programs, within 6 months of the effective date of the
directive. For new applicants, prior to registration.
For existing participants in the Canadian Lumber Programs, within 6 months of the effective date of the
directive. For new applicants, prior to registration.
Issuance of facility registration number by CFIA
Upon approval of facility's Manual.
Upon approval of facility's Manual.
Evaluation Audit conducted by Service Provider in consultation with the CFIA
For new applicants, to be conducted prior to registration. For existing participants, conducted within
the first year of registration, or as a result of suspension from the program to confirm that a facility has adequately
addressed the non-conformities and initiated quality activities that would ensure that future non-conformities may be
avoided.
For new applicants, to be conducted prior to registration. For existing participants, conducted within
the first year of registration, or as a result of suspension from the program to confirm that a facility has adequately
addressed the non-conformities and initiated quality activities that would ensure that future non-conformities may be
avoided.
Verification Audit conducted by the Service Provider (i.e., a review of the organizational structure, procedures, processes and resources used by a
registered facility in implementing the certification program)
A minimum of 4 times a year.
A minimum of 4 times a year in the first year of registration or re-registration following suspension
and 2 times a year in subsequent years.
Follow-up audit (i.e., performed to verify
that corrective actions ordered have been completed and that facility operations continue to meet the specifications of the
facility Manual)
At any time until non-conformances are corrected to the satisfaction of the Service Provider and/or
CFIA.
At any time until non-conformances are corrected to the satisfaction of the Service Provider and/or
CFIA.
Systems Audits conducted by CFIA
A representative sample (up to 33%) of registered facilities on an annual basis.
A representative sample (up to 33%) of registered facilities on an annual basis.
Following a facility audit conducted by a Service Provider, the Service Provider will provide a report to the facility
within 5 working days of its audit. In the event that corrective actions are required to address non-conformances which has
been identified during the audit, the Service Provider will take the following additional actions:
For a minor non-conformance, as outlined under the Quality System Guidelines for
Facility Registration under the Wood Product Certification Programs Canadian Heat Treated Wood Products
Certification Program (CHTWPCP) and Canadian Wood Packaging Certification Program (CWPCP) (QSM-02):
the Service Provider shall verify that the corrective actions requested has been completed by
the facility within a reasonable time frame, not exceeding one month from the date of initial notification of the
non-conformance by the Service Provider;
the Service Provider shall provide the CFIA in its quarterly
report information regarding the non-conformance, the planned corrective action and follow-up confirmation that the
corrective action has been completed.
for a major non-conformance, as defined under the Quality System Guidelines for
Facility Registration under the Wood Product Certification Programs Canadian Heat Treated Wood Products
Certification Program (CHTWPCP) and Canadian Wood Packaging Certification Program (CWPCP) (QSM-02):
the Service Provider shall deliver to the registered facility, and to the CFIA a notice in writing with a description of the non-conformance and the
required corrective action within 3 working days of such non-conformance;
the Service Provider shall request the facility to take corrective action within a time frame appropriate to address the
non-conformance but not to exceed 10 working days;
the Service Provider shall follow-up on corrective actions taken by the facility as often as required to verify full
compliance within 10 working days of initial notification of the corrective action due date;
the Service Provider shall provide written confirmation to the CFIA, that the required corrective action, or other actions, which has not
been taken within 3 working days;
where the major non-conformance compromises the integrity of the program, the Service Provider will suspend the facility
from the program and will remove all stamps and certificates relevant to this program and will notify the CFIA within 3 working days following the audit.
Where the CFIA has been notified of
a major non-conformance as set out herein, the CFIA may apply an
interim suspension of the facility's registration under the CHTWPCP, and will provide notice thereof to the
facility and the Service Provider immediately upon the decision to suspend by the CFIA. During the suspension period, the registered facility will not be
permitted to certify wood packaging products for export as outlined in the CHTWPCP.
Should the CFIA determine in its
sole and unfettered discretion that the proposed corrective action or implemented corrective action by the Service Provider
is unsatisfactory, the Parties agree that the CFIA reserves the
right to directly impose or implement upon the registered facility whatever corrective action it deems necessary to correct
the non-conformance.
In the event of a non-conformance by a registered facility, the CFIA may increase the frequency of inspection of the facility, until
corrective actions satisfactory to the CFIA are verified by the
Service Provider as being complete.
Where the CFIA determines, in its
sole and unfettered discretion, that a registered facility is consistently unable to maintain conformance with the CHTWPCP or that a registered facility's
non-conformance jeopardizes the integrity of the CHTWPCP, the CFIA may suspend or revoke the registered facility's registration
under the CHTWPCP. In such event, the
CFIA program officer will notify the Service Provider and the
registered facility in writing of this action.
If the facility's corrective actions and quality are deemed sufficient by the CFIA, the CFIA
will lift the suspension will assign the facility a new inspection frequency. Once the facility has demonstrated to the
Service Provider on-going compliance with the requirements of the CHTWPCP, the Service Provider will reduce the
frequency of inspection to that specified the Quality System Procedures for The Export Certification Programs, CHTWPCP (D-03-02) and the CWPCP (D-01-05).
The Service Provider must describe procedures for conducting inspections (provide examples of checklists and reports) and
reporting results (this may all be described in a separate inspection manual). The Service Provider must describe procedures
for reporting non-conformity and, if major, notifying the CFIA
and must describe procedures for following up major non-conformity and reporting to the CFIA.
In the evaluation and surveillance audit the following information must be included:
Type of audit: Evaluation, or Verification audit:
Date of Audit:
Date of Previous Audit:
Audit Report No.:
Facility Name:
Address:
Location:
Lead Auditor:
Team Members:
Summary of Audit:
List of minor non-conformances:
Corrective Action Requests:
List of major non-conformances:
Corrective Action Requests:
Facility Compliance status: Compliant Suspended
Signature of lead Auditor:
Date:
Signature of Facility Representative:
Date:
The Service Provider will provide to the CFIA annually, on or before March 31 of each year, a detailed report in
writing of all audits, inspections and follow-up activities completed during that fiscal year. The report will include, but
will not be limited to, a listing of facilities by Service Provider, information on the total number of audits performed by
each Service Provider, a list of the facilities audited, a list of major non-conformances found, number of facilities added
or deleted from the program and relevant dates.
The Service Provider will advise the CFIA in writing as soon as it comes to the attention of the Service
Provider that a registered facility ceases to operate under agreement with the Service Provider or has withdrawn from the
CHTWPCP.
The Service Provider will complete and date a report of each inspection of a registered
facility, and such reports will be kept on file by the Service Provider for periodic review by the CFIA at its discretion.
The Service Provider will maintain for a period of at least two (2) years all records
pertaining to its verification of facilities, including but not limited to: assessment reports for registration, audit
reports, reports of non-conformances and follow-up audits, authorizations of changes to Manuals and to the training of
Service Provider staff.
The Service Provider will complete and date a report of each audit conducted on registered
facilities they have audited in the process, and such reports will be kept on file by the Service Provider for periodic
review by the CFIA.
The Service Provider will meet any other reporting requirements as mutually agreed upon from
time to time.
A Registered Facility will be considered for cancellation, in full or in part, if:
requested by the Service Provider; or
an audit identifies systematic, ongoing failure of the facility to adequately discharge its
duties.
If a registered facility is permanently removed from the program, resold, operating under new managements, operating
under a new Certificate of Registration and Registration Number or voluntarily withdraws from the CHTWPCP, their facility number shall be
cancelled from use and removed from the CFIA list of registered
wood packaging facilities or the CFIA list of registered wood
packaging treatment facilities. The facility registration number must not be re-used.
The CFIA Auditor or Service provider forwards an e-mail to the
Area Forestry Network Specialist advising that the facility has been cancelled from the CHTWPCP. The CFIA auditor or Service provider will send a letter to the facility, if
possible, providing officially notification that the facility has been cancelled from the program.
The CFIA will arrange for the cancelled facility registration
number to be removed from the CFIA Forestry Website.
Facilities or treatment facilities that have been cancelled from the CHTWPCP must completely re-register starting
with submission of the CHTWPCP
application form.
Where the CFIA determines in its
sole and unfettered discretion that the Service Provider has not complied with the requirements of the CHTWPCP or is in default of any representation,
covenant, term or condition of this Agreement, the CFIA will
provide the Service Provider with a report detailing such non-compliance and/or default.
Upon receipt of such report, the Service Provider will immediately begin remedying such
non-compliance and/or default and will demonstrate to the CFIA
within one (1) month that such non-compliance and/or default has been remedied to the satisfaction of the CFIA, failing which, the CFIA will be entitled to suspend or revoke, at its sole discretion,
recognition of the Service Provider as a Service Provider under the CHTWPCP and to communicate the same to the
registered facilities contracting with the Service Provider.
The CFIA may, in its sole and
unfettered discretion, increase the frequency of inspections of the Service Provider where non-compliance or defaults exist
as described in this section.
Facilities recommended for registration to the CFIA by a Service Provider and registered by CFIA and which has been subsequently cancelled from the program, will be
required to seek the service of another CFIA recognized Service
Provider.
Fees payable by facilities for participation under this program, will be made directly to the CFIA. The CFIA
will be charging fees in accordance with the Canadian Food Inspection Agency Fees Notice. Individuals requiring more
information on fee schedules may contact any CFIA regional offices.
Note: At time of publication of this document, the annual CFIA
registration fee for facilities participating under this program is $400.00. The CFIA reserves the right to charge an additional fee for its service, in
accordance with the Canadian Food Inspection Agency Fees Notice, for follow-up inspection activities performed to verify
that the requested corrective actions have been taken by the facilities, to address the major non-conformances.
I (name of owner or person with possession, care, or control of the facility), hereby acknowledge
that I have read and understand the following terms and conditions as they apply to the collection of information related to
the facility located at (address).
The Canadian Wood Packaging Certification Program
1. I have been informed and understand that:
The Canadian Food Inspection Agency (CFIA) has recognized (full legal name of
the Service Provider) as a Service Provider under the Canadian Heat Treated Wood Products Certification Program (CHTWPCP)
for Export established in Directive D-03-02.
The (full legal name of the Service Provider) is responsible for collecting, reviewing
and reporting to the CFIA on the facility's Application for
Registration to the Canadian Heat Treated Wood Products Certification Program (CHTWPCP) and Manual.
The CFIA is responsible for the
registration, suspension or cancellation of registration of any facility registered in the CHTWPCP.
Legal Ownership/Possession/Care or Control
2. (1) I hereby confirm that I am the owner, or person with legal possession, care, or
control of the facility in question and that I have the full and complete right to grant permission to (full legal name of the Service Provider) to disclose to the CFIA the following information and documents:
name of the facility;
address of the facility;
telephone number of the facility;
the facility's Application for Registration to the Canadian Heat Treated Wood Products Certification Program
(CHTWPCP); and
the facility's Manual.
And furthermore, I grant permission to (full legal name of the Service Provider) to disclose said information
and materials.
(2) I further confirm that I have the right and authority to grant and provide such permission to disclose the
information and documents as described in subparagraph 2(1) without the consent of any third Party and without violating the
rights of any third Party.
I hereby confirm the truth of the above statements and that I have read and understand accept and agree with the above
statements and terms.
Signed this day of , 201 at (address)
Owner/Person with Possession, Care, or Control of the Establishment