Chapter 19 Appendices
Appendix 20 Prerequisite Programs Cross-Reference with FSEP Prerequisite Program Bullets
- A.1.1 Outside Property
- A.2.1 Building Design, Construction and Maintenance
- A.2.2 Lighting
- A.2.3 Ventilation
- A.2.4 Waste & Inedible/Food Waste Program
- A.3.1 Employees Facilities
- A.3.2 Hand-washing Stations and Sanitizing Installations
- A.4.1 Water/Ice/Steam Quality, Protection and Supply
- B 1.1 Food Carriers
- B.2.1 Purchasing / Receiving / Shipping
- B.2.2 Storage
- C.1.1 Design & Installation
- C.1.2 Equipment Maintenance Program and Calibration
- D.1.1 General Food Hygiene Training
- D.1.2 Technical Training Program
- D.2.1 General Food Hygiene Program
- E.1.1 Sanitation Program
- E.2.1 Pest Control Program
- F 1.1 Recall Plan
- F 1.2 Product coding and labelling
- G.1.1 Allergen Control Program
| FSEP Manual 2010 Prerequisite Program Requirements | Reference to Chapter 10 DEIM – Prerequisite Programs |
|---|---|
| A.1.1.1 Building facility is located away from or protected against potential sources of external contaminants that may compromise the safety of food. The surrounding/roadways are free of debris and refuse, adequately drained and maintained to minimize environmental hazards. |
1.10.01.03 |
| FSEP Manual 2010 Prerequisite Program Requirements | Reference to Chapter 10 DEIM – Prerequisite Programs |
|---|---|
| A.2.1.1 The building is designed and constructed:
|
1.10.01.02 1.10.01.03 1.10.01.04 1.10.01.05 1.10.01.06 1.10.01.08 1.10.01.09 1.10.02.03 |
| A.2.1.2 The building is maintained so:
|
1.10.01.03 1.10.01.04 |
| FSEP Manual 2010 Prerequisite Program Requirements | Reference to Chapter 10 DEIM – Prerequisite Programs |
|---|---|
| A.2.2.1 Lighting is appropriate such that food colour is not altered and the intended production or inspection activity can be effectively conducted. |
1.10.01.04 |
| A.2.2.2 Light bulbs and fixtures located in areas where there is exposed food or packaging materials are of a safety type or are protected to prevent contamination of food in case of breakage. |
1.10.01.04 |
| FSEP Manual 2010 Prerequisite Program Requirements | Reference to Chapter 10 DEIM – Prerequisite Programs |
|---|---|
| A.2.3.1 Ventilation provides sufficient air exchanges to prevent unacceptable accumulations of steam, condensation or dust and to remove contaminated air. Filters are cleaned or replaced as appropriate. |
1.10.01.04 1.10.01.10 |
| A.2.3.2 Ventilation systems ensure that air flows from the least contaminated areas to the most contaminated areas. |
1.10.01.04 |
| A.2.3.3 Where required, ambient air, compressed air or gases utilized in processing equipment that contact product or packaging are appropriately sourced and treated to minimize contamination of product and packaging. |
1.10.03.02 (air in contact with product/ packaging) Appendix 2 |
| FSEP Manual 2010 Prerequisite Program Requirements | Reference to Chapter 10 DEIM – Prerequisite Programs |
|---|---|
| A.2.4.1 The establishment has and implements documented procedures to control the hazards associated with waste and inedible/food waste products. The procedures shall include but are not limited to:
|
Not all of these bullets will apply to the dairy program 1.10.01.05 |
| FSEP Manual 2010 Prerequisite Program Requirements | Reference to Chapter 10 DEIM – Prerequisite Programs |
|---|---|
| A.3.1.1 Washrooms have hot and cold or warm potable running water, soap dispensers, soap, sanitary hand drying equipment or supplies and cleanable waste receptacles. Hand washing notices are posted in appropriate areas. |
1.10.01.06 1.10.01.07 |
| A.3.1.2 As required, washrooms, lunchrooms and change rooms are provided with adequate floor drainage and ventilation. They are maintained in a manner to prevent contamination. |
1.10.01.06 |
| FSEP Manual 2010 Prerequisite Program Requirements | Reference to Chapter 10 DEIM – Prerequisite Programs |
|---|---|
| A.3.2.1 Where required or appropriate, areas of the establishment are provided with an adequate number of conveniently located hands free hand-washing stations with trapped waste pipes to drains. Hand-washing stations are properly maintained and are provided with hot and cold or warm potable running water, soap dispensers, soap, sanitary hand drying equipment or supplies and cleanable waste receptacles. Hand-washing notices are posted in appropriate areas. |
1.10.01.06 1.10.01.07 |
| A.3.2.2 Where required/appropriate, areas of the establishment are provided with sanitizing installations, such as:
|
1.10.01.06 |
| FSEP Manual 2010 Prerequisite Program Requirements | Reference to Chapter 10 DEIM – Prerequisite Programs |
|---|---|
| A.4.1.1 The establishment has and implements documented water safety procedures to ensure that water and ice meet the potability requirements of the appropriate regulatory authority. The water safety procedures shall include but are not limited to:
|
1.10.01.09 Appendix 12 A |
| A.4.1.2 Where applicable, the establishment has and implements documented water treatment procedures to ensure that:
|
1.10.01.09 Appendix 1 Appendix 12 Appendix 12 A |
| A.4.1.3 Where required, hoses, taps or other similar sources of possible contamination are designed to prevent back-flow or back siphonage. |
1.10.01.09 Appendix 12 C |
| A.4.1.4 Where filters are used they are kept effective and maintained in a sanitary manner. |
1.10.01.09 |
| A.4.1.5 The volume, temperature and pressure of the potable water/steam are adequate for all operational and cleanup demands. |
1.10.01.09 |
| A.4.1.6 Where it is necessary to store water or ice, storage facilities are adequately designed, constructed, and maintained to prevent contamination. |
1.10.01.09 |
| FSEP Manual 2010 Prerequisite Program Requirements | Reference to Chapter 10 DEIM – Prerequisite Programs |
|---|---|
| B.1.1.1 Carriers used for transport of food:
|
1.10.02.02 |
| B.1.1.2 Carriers are loaded, arranged and unloaded in a manner that:
|
1.10.02.02 |
| FSEP Manual 2010 Prerequisite Program Requirements | Reference to Chapter 10 DEIM – Prerequisite Programs |
|---|---|
| B.2.1.1 The establishment has and implements documented purchasing procedures to ensure that:
|
1.10.02.01 (documented purchasing procedures not part of DEIM) 1.10.02.03 1.10.02.04 1.10.02.08 1.10.01.04 |
| B.2.1.2 Returned, defective or suspect product is clearly identified and isolated in a designated storage area, assessed and dispositioned appropriately. |
1.10.02.05 |
| B.2.1.3 Where applicable, receiving of live animals is controlled as per regulatory requirements. Only approved raw materials, ingredients and materials are received into the establishment. Incoming raw materials and ingredients are assessed at receiving, where possible, to ensure that the purchasing specifications have been met.* *Where organoleptic inspections are not effective as a means of confirming material acceptability for these materials, certificate of analysis may be used as a means to verify the commitment made by the suppliers. |
1.10.02.03 1.10.02.04 |
| B.2.1.4 All food safety specifications or requirements of the finished product have been met prior to shipping to retail/the customer. (e.g., temperature, certificate of analysis) Finished product is adequately protected against intentional or unintentional contamination and deterioration prior to shipping. |
1.10.07.03 1.10.07.04 1.10.02.02 |
| FSEP Manual 2010 Prerequisite Program Requirements | Reference to Chapter 10 DEIM – Prerequisite Programs |
|---|---|
| B.2.2.1 Temperatures of storage areas, processing areas, coolers and freezers meet regulated and/or acceptable temperatures. |
1.10.02.05 1.10.02.06 1.10.02.07 |
| B.2.2.2 Ingredients, finished products and packaging materials are handled and stored in a manner to prevent damage, deterioration and contamination. Where applicable, ingredients and finished products are prepared in a manner to prevent time and temperature abuse associated with food safety or shelf life. Where appropriate, rotation is controlled to prevent deterioration. |
1.10.02.03 (B) 1.10.02.05 1.10.02.06 |
| B.2.2.3 Non-food chemicals are received and stored in a dry, adequately ventilated area which is designed such that there is no possibility for cross-contamination of food, packaging materials or food contact surfaces. When required for ongoing use in food handling areas, non-food chemicals are stored in a manner that prevents contamination of food, food contact surfaces or packaging material. Non-food chemicals are mixed in clean, correctly labelled containers and dispensed and handled only by authorized and properly trained personnel. |
1.10.02.08 |
| FSEP Manual 2010 Prerequisite Program Requirements | Reference to Chapter 10 DEIM – Prerequisite Programs |
|---|---|
| C.1.1.1 Equipment is designed, constructed and installed to ensure that:
|
1.10.01.08 1.10.03.01 1.10.03.04 Chapter 16 |
| FSEP Manual 2010 Prerequisite Program Requirements | Reference to Chapter 10 DEIM – Prerequisite Programs |
|---|---|
| C.1.2.1 The establishment has and implements a documented Preventative Equipment Maintenance Program which includes but is not limited to:
|
1.10.03.01 1.10.03.03 1.10.03.04 1.10.03.05 |
| C.1.2.2 The establishment has and implements a documented Equipment Calibration Program which includes but is not limited to:
|
1.10.03.01 1.10.03.05 Chapter 18 Appendix 5 Appendix 6 |
| FSEP Manual 2010 Prerequisite Program Requirements | Reference to Chapter 10 DEIM – Prerequisite Programs |
|---|---|
| D.1.1.1 The establishment has and implements a documented general food hygiene training program which includes but is not limited to:
|
1.10.04.01 |
| FSEP Manual 2010 Prerequisite Program Requirements | Reference to Chapter 10 DEIM – Prerequisite Programs |
|---|---|
| D.1.2.1 The establishment has and implements a documented Technical Training Program which includes but is not limited to:
|
1.10.04.01 |
| FSEP Manual 2010 Prerequisite Program Requirements | Reference to Chapter 10 DEIM – Prerequisite Programs |
|---|---|
| D.2.1.1 The establishment has and implements a documented General Food Hygiene Program which includes, but is not limited to:
|
1.10.04.02 1.10.04.03 1.10.04.04 1.10.01.11 |
| FSEP Manual 2010 Prerequisite Program Requirements | Reference to Chapter 10 DEIM – Prerequisite Programs |
|---|---|
| E.1.1.1 The establishment has and implements a documented Sanitation Program which includes but is not limited to:
|
1.10.05.01 1.10.05.02 1.10.05.03 1.10.07.03 |
| FSEP Manual 2010 Prerequisite Program Requirements | Reference to Chapter 10 DEIM – Prerequisite Programs |
|---|---|
| E.2.1.1 The establishment has and implements a documented Pest Control Program which includes but is not limited to:
|
1.10.05.04 |
| FSEP Manual 2010 Prerequisite Program Requirements | Reference to Chapter 10 DEIM – Prerequisite Programs |
|---|---|
| F.1.1.1 The establishment has and implements a documented Recall Plan which includes but is not limited to: See FSEP Manual – F.1.1.1 |
1.10.06 |
| FSEP Manual 2010 Prerequisite Program Requirements | Reference to Chapter 10 DEIM – Prerequisite Programs |
|---|---|
| F.1.2.1 The establishment has and implements documented operational procedures to ensure that:
|
1.10.06 1.10.07.01 1.10.07.02 |
| FSEP Manual 2010 Prerequisite Program Requirements | Reference to Chapter 10 DEIM – Prerequisite Programs |
|---|---|
| G.1.1.1 Where applicable, procedures and/or policies are developed and implemented to ensure proper control of new or modified product formulations. This must include a minimum of:
|
1.10.07.01 1.10.07.02 |
| G.1.1.2 Where applicable, procedures and/or policies related to purchasing of ingredients are developed and implemented to ensure proper control and identification of allergens for incoming ingredients. This must include a minimum of:
|
1.10.02.03 1.10.07.01 1.10.07.02 (DEIM not as detailed as in FSEP) |
| G.1.1.3 Where applicable, procedures and/or policies are developed and implemented to ensure proper control of new or modified labels. This must include a minimum of:
|
1.10.07.01 1.10.07.02 |
| G.1.1.4 Where applicable, procedures and/or policies related to receiving of ingredients and externally printed labels are developed and implemented to ensure that:
|
1.10.02.03 1.10.07.02 |
| G.1.1.5 Where applicable, procedures associated with Weighing/Blending/Mixing/Formulation are developed and implemented to ensure that the correct ingredient is added to the correct product as indicated in the formula. This must include a minimum of:
|
1.10.07.01 1.10.07.02 |
| G.1.1.6 Where applicable, procedures and/or policies related to the use of rework are developed and implemented to ensure that the rework formulation ingredients and the product formulation ingredients match, specifically as it applies to allergen ingredients. |
1.10.02.05 (F) 1.10.07.01 1.10.07.02 |
| G.1.1.7 Where applicable, procedures related to labelling of finished product are developed and implemented to ensure that the finished product label information accurately represents the product name and the composition of the product on which the label is affixed This must include a minimum of:
|
1.10.07.02 |
| G.1.1.8 Where applicable, procedures and/or policies for disposal of obsolete materials are developed and implemented to prevent their inadvertent use. Obsolete materials include:
|
Requirement not in DEIM |
| G.1.1.9 Where applicable, procedures and/or policies are developed and implemented to control cross-contamination of undeclared allergens in the food products. Procedures include as a minimum, the management and control of:
|
1.10.07.02 (DEIM not as detailed as in FSEP). 1.10.05.01 1.10.04.02 1.10.04.04 1.10.02.05 (B) |
- Date modified: