Processed Products Establishment Inspection Manual
Chapter 4 - Generic Inspection Standard
- 4.1 Premises
- 4.2 Transportation and Storage
- 4.3 Equipment
- 4.4 Personnel
- 4.5 Sanitation (and Pest Control)
- 4.6 Complaints and Recalls
- 4.7 Records
4.1 Premises
| Section | Task Number | Manufacturing Controls | Low Acid Foods (LAF) in HSC | Fresh Pack (ALAF) | Fermented Pack (ALAF) | Acid Foods | Frozen Foods | Low Water Activity |
| 4.1.1.1 | 0001 | Outside Property and Building | X | X | X | X | X | X |
| Section | Task Number | Manufacturing Controls | Low Acid Foods (LAF) in HSC | Fresh Pack (ALAF) | Fermented Pack (ALAF) | Acid Foods | Frozen Foods | Low Water Activity |
| 4.1.2.1 | 101 | Design, Construction and Maintenance | X | X | X | X | X | X |
| 4.1.2.2 | 102 | Lighting | X | X | X | X | X | X |
| 4.1.2.3 | 103 | Ventilation | X | X | X | X | X | X |
| 4.1.2.4 | 104 | Waste Disposal | X | X | X | X | X | X |
| Section | Task Number | Manufacturing Controls | Low Acid Foods (LAF) in HSC | Fresh Pack (ALAF) | Fermented Pack (ALAF) | Acid Foods | Frozen Foods | Low Water Activity |
| 4.1.3.1 | 201 | Employee Facilities | X | X | X | X | X | X |
| 4.1.3.2 | 202 | Equipment Cleaning and Sanitizing Facilities | X | X | X | X | X | X |
| Section | Task Number | Manufacturing Controls | Low Acid Foods (LAF) in HSC | Fresh Pack (ALAF) | Fermented Pack (ALAF) | Acid Foods | Frozen Foods | Low Water Activity |
| 4.1.4.1 | 301 | Water and Ice | X | X | X | X | X | X |
| 4.1.4.2 | 302 | Steam | X | X | X | X | X | X |
| 4.1.4.3 | 303 | Water/Ice/Steam Quality Records | X | X | X | X | X | X |
4.2 Transportation and Storage
| Section | Task Number | Manufacturing Controls | Low Acid Foods (LAF) in HSC | Fresh Pack (ALAF) | Fermented Pack (ALAF) | Acid Foods | Frozen Foods | Low Water Activity |
| 4.2.1.1 | 401 | Food Carriers | X | X | X | X | X | X |
| 4.2.1.2 | 402 | Temperature Controls | X | X | X | X | X | X |
| Section | Task Number | Manufacturing Controls | Low Acid Foods (LAF) in HSC | Fresh Pack (ALAF) | Fermented Pack (ALAF) | Acid Foods | Frozen Foods | Low Water Activity |
| 4.2.2.1 | 501 | Incoming Materials Storage | X | X | X | X | X | X |
| 4.2.2.2 | 502 | Non Food Chemicals - Receiving and Storage | X | X | X | X | X | X |
| 4.2.2.3 | 503 | Finished Product Storage | X | X | X | X | X | X |
| 4.2.2.4 | 504 | Finished Product Storage - Frozen | X |
4.3 Equipment
| Section | Task Number | Manufacturing Controls | Low Acid Foods (LAF) in HSC | Fresh Pack (ALAF) | Fermented Pack (ALAF) | Acid Foods | Frozen Foods | Low Water Activity |
| 4.3.1.1 | 601 | Design and Installation | X | X | X | X | X | X |
| 4.3.1.2 | 602 | Food Contact Surfaces | X | X | X | X | X | X |
| 4.3.1.3 | 603 | Equipment Maintenance and Calibration Program | X | X | X | X | X | X |
| 4.3.1.4 | 604 | Equipment Maintenance Records | X | X | X | X | X | X |
| 4.3.1.5 | 605 | Equipment Calibration Records | X | X | X | X | X | X |
| Section | Task Number | Manufacturing Controls | Low Acid Foods (LAF) in HSC | Fresh Pack (ALAF) | Fermented Pack (ALAF) | Acid Foods | Frozen Foods | Low Water Activity |
| 4.3.2.1 | 701 | Preparation/Blending Equipment and Instrumentation | X | X | X | X | X | X |
| 4.3.2.2 | 702 | Filling Equipment and Instrumentation | X | X | X | X | X | X |
| 4.3.2.3 | 703 | Container Closure Equipment | X | X | X | X | X | X |
| Section | Task Number | Manufacturing Controls | Low Acid Foods (LAF) in HSC | Fresh Pack (ALAF) | Fermented Pack (ALAF) | Acid Foods | Frozen Foods | Low Water Activity |
| 4.3.3.1 | 801 | Design, Installation and Maintenance (Still Steam Retort) | X | |||||
| 4.3.3.2 | 802 | Retort Instrumentation | X |
| Section | Task Number | Manufacturing Controls | Low Acid Foods (LAF) in HSC | Fresh Pack (ALAF) | Fermented Pack (ALAF) | Acid Foods | Frozen Foods | Low Water Activity |
| 4.3.4.1 | 901 | Post-Process Cooling Canal and Handling Equipment | X | X | X | X | X | |
| 4.3.4.2 | 902 | Low Vacuum Detection Equipment | X | X | X | X | X |
4.4 Personnel
| Section | Task Number | Manufacturing Controls | Low Acid Foods (LAF) in HSC | Fresh Pack (ALAF) | Fermented Pack (ALAF) | Acid Foods | Frozen Foods | Low Water Activity |
| 4.4.1.1 | 1001 | General Food Hygiene Training | X | X | X | X | X | X |
| 4.4.1.2 | 1002 | Technical Training | X | X | X | X | X | X |
| Section | Task Number | Manufacturing Controls | Low Acid Foods (LAF) in HSC | Fresh Pack (ALAF) | Fermented Pack (ALAF) | Acid Foods | Frozen Foods | Low Water Activity |
| 4.4.2.1 | 1101 | Cleanliness and Conduct | X | X | X | X | X | X |
| 4.4.2.2 | 1102 | Communicable Diseases/Injuries | X | X | X | X | X | X |
4.5 Sanitation (and Pest Control)
| Section | Task Number | Manufacturing Controls | Low Acid Foods (LAF) in HSC | Fresh Pack (ALAF) | Fermented Pack (ALAF) | Acid Foods | Frozen Foods | Low Water Activity |
| 4.5.1.1 | 1201 | Written Sanitation Program and Effectiveness Evaluation | X | X | X | X | X | X |
| 4.5.1.2 | 1202 | Equipment Cleanliness | X | X | X | X | X | X |
| 4.5.1.3 | 1203 | Premises Cleanliness | X | X | X | X | X | X |
| 4.5.1.4 | 1204 | Sanitation Records | X | X | X | X | X | X |
| Section | Task Number | Manufacturing Controls | Low Acid Foods (LAF) in HSC | Fresh Pack (ALAF) | Fermented Pack (ALAF) | Acid Foods | Frozen Foods | Low Water Activity |
| 4.5.2.1 | 1301 | Pest Control Program | X | X | X | X | X | X |
| 4.5.2.2 | 1302 | Pest Control Records | X | X | X | X | X | X |
4.6 Complaints and Recalls
| Section | Task Number | Manufacturing Controls | Low Acid Foods (LAF) in HSC | Fresh Pack (ALAF) | Fermented Pack (ALAF) | Acid Foods | Frozen Foods | Low Water Activity |
| 4.6.1.1 | 1401 | Product Complaints | X | X | X | X | X | X |
| 4.6.1.2 | 1402 | Complaint Records | X | X | X | X | X | X |
| Section | Task Number | Manufacturing Controls | Low Acid Foods (LAF) in HSC | Fresh Pack (ALAF) | Fermented Pack (ALAF) | Acid Foods | Frozen Foods | Low Water Activity |
| 4.6.2.1 | 1501 | Recall Plan | X | X | X | X | X | X |
| 4.6.2.2 | 1502 | Product Code Identification | X | X | X | X | X | X |
| 4.6.2.3 | 1503 | Recall Capability | X | X | X | X | X | X |
| 4.6.2.4 | 1504 | Distribution Records | X | X | X | X | X | X |
4.7 Records
| Section | Task Number | Manufacturing Controls | Low Acid Foods (LAF) in HSC | Fresh Pack (ALAF) | Fermented Pack (ALAF) | Acid Foods | Frozen Foods | Low Water Activity |
| 4.7.1.1 | 1601 | General Record Requirements | X | X | X | X | X | X |
| 4.7.1.2 | 1602 | General Regulatory Requirements | X | X | X | X | X | X |
Total number of tasks for each product type (inspection scope)
45 - Low Acid Foods (LAF) in HSC
43 - Fresh Pack (ALAF)
43 - Fermented Pack (ALAF)
43 - Acid Foods (AF)
42 - Frozen Foods (FF)
43 - Low Water Activity (LAw)
| 4.1 | Premises |
|---|---|
| 4.1.1 | Building Exterior |
| 4.1.1.1 | Outside Property and Building |
| Task 0001 | April 1, 2002 |
| Principle | Buildings and surrounding areas are designed, constructed and maintained in a manner to prevent conditions which may result in the contamination of food. |
| Assessment Criteria | Grounds, Roadways and Drainage
Exterior Building Structure
|
| Rating Guide | Examples |
| Rating I |
|
| Rating II |
|
| Rating III |
|
| Legal Authorities | PPR 13 (a) Free or debris or refuse (b) Good drainage (c) Not in proximity or source of pollution, pest harbourage 14(1) (a) Sound construction - good repair (b) Acceptable materials (c) Protected against the entrance of any vermin |
| 4.1 | Premises |
|---|---|
| 4.1.2 | Building Interior |
| 4.1.2.1 | Design, Construction and Maintenance |
| Task 101 | April 1, 2002 |
| Principle | Building interiors and structures are designed, constructed and maintained in a manner to prevent conditions which may result in the contamination of food. |
| Assessment Criteria | Floors, Walls, Ceilings
Windows and Doors
Process Flow Separation
|
| Rating Guide | Examples |
| Rating I |
|
| Rating II |
|
| Rating III |
|
| Legal Authorities | PPR 14(1)(a) Sound construction - good repair (b) Acceptable materials (c) Protected against entrance of birds, insects etc. (1)(d) Floors , walls and ceilings -cleanable and impervious to moisture (1)(g) Separation of incompatible operations 16(5) Acceptable materials used for repairs |
| 4.1 | Premises |
|---|---|
| 4.1.2 | Building Interior |
| 4.1.2.2 | Lighting |
| Task 102 | January 31, 2008 |
| Principle | Light is adequate for the activity being conducted. Where appropriate, light bulbs and fixtures are protected to prevent contamination of food. |
| Assessment Criteria | Lighting is appropriate such that the intended production or inspection activity can be effectively conducted. The lighting does not alter food colour and is not be less than the following intensity:
* Inspection areas are defined as any point where the food product or container is visually inspected or instruments are monitored (e.g., empty container evaluation, product sorting, inspection, grading and sampling). Light bulbs and fixtures located in areas where there is exposed food are of a safety type or are protected to prevent contamination of food in case of breakage. |
| Rating Guide | Examples |
| Rating I |
|
| Rating II |
|
| Rating III |
|
| Legal Authority | PPR 14(1)(e) Adequate lighting (f) Light bulbs and fixtures - safety type 16(6) 540 lux for product sorting and inspection |
| 4.1 | Premises |
|---|---|
| 4.1.1 | Building Interior |
| 4.1.2.3 | Ventilation |
| Task 103 | April 1, 2002 |
| Principle | Adequate ventilation is provided to prevent excessive heat, steam, condensation, and dust, and to remove contaminated air. |
| Assessment Criteria |
|
| Rating Guide | Examples |
| Rating I |
|
| Rating II |
|
| Rating III |
|
| Legal Authorities | PPR 14(1)(c) Protected against entrance of insect, birds etc. (e) Adequate ventilation system (h)(iii) Dressing rooms, lunch rooms and lavatories well ventilated |
| 4.1 | Premises |
|---|---|
| 4.1.2 | Building Interior |
| Task 4.1.2.4 | Waste Disposal |
| Task 104 | April 1, 2002 |
| Principle | Sewage, effluent and waste storage and disposal systems are designed, constructed and maintained to prevent contamination. |
| Assessment Criteria |
|
| Rating Guide | Examples |
| Rating I |
|
| Rating II |
|
| Rating III |
|
| Legal Authority | PPR 14(1)(e) Plumbing meets requirements of operation (j) Adequate disposal (k) Drainage and sewage facilities:
(11) Waste containers identified |
| 4.1 | Premises |
|---|---|
| 4.1.3 | Sanitary Facilities |
| 4.1.3.1 | Employee Facilities |
| Task 201 | April 1, 2002 |
| Principle | Employee facilities are designed, constructed and maintained to permit effective employee hygiene and to prevent contamination. |
| Assessment Criteria |
|
| Rating Guide | Examples |
| Rating I |
|
| Rating II |
|
| Rating III |
|
| Legal Authority | PPR 14(1)(h) Employees facilities: dressing rooms, lunchrooms and lavatories are:
14(1)(i) Hot and cold potable water 16(4) Handwashing notices(7) Maintained to prevent any odours or fumes pervading food handling rooms |
| 4.1 | Premises |
|---|---|
| 4.1.3 | Sanitary Facilities |
| 4.1.3.2 | Equipment Cleaning and Sanitizing Facilities |
| Task 202 | April 1, 2002 |
| Principle | Facilities for cleaning and sanitizing equipment are adequately designed, constructed and maintained to prevent contamination. |
| Assessment Criteria |
|
| Rating Guide | Examples |
| Rating I |
|
| Rating II |
|
| Rating III |
|
| Legal Authorities | PPR 14(1) (a) Sound construction good repair (e) Adequate ventilation and plumbing (g) Separation of incompatible operations (i) Adequate quantity and pressure of hot and cold potable water (n) Facilities for washing, cleaning and sanitizing equipment |
| 4.1 | Premises |
|---|---|
| 4.1.4 | Water/Ice/Steam Quality |
| Task 4.1.4.1 | Water and Ice |
| Task 301 | January 31, 2008 |
| Principle | The potability of hot and cold water, and ice is controlled to prevent contamination. |
| Assessment Criteria | Water that is used solely for fire protection, boilers or auxiliary services (e.g. cooling of compressor heads) does not have to meet the same criteria for potability. It must be contained in a closed system (see "Water system design" for further details) Water testing Water meets the requirements of Health Canada's "Guidelines for Canadian Drinking Water Quality".
Ice testing Ice used as an ingredient or in direct contact with food is made from potable water and is protected from contamination
Water treatment Source water (municipal or well) is treated and monitored if it poses a contamination risk to the product. In plant water is treated and monitored as appropriate to the intended purpose if it is:
The treatment method (ozone, chlorine, UV, filtration etc.) and the factors relating to its efficacy (turbidity, pH, time, temperature, etc.) are monitored and controlled to prevent contamination.
Water treatment chemicals, when used, are listed in the "Reference Listing of Accepted Construction Materials, Packaging Materials and Non Food Chemical Products", published by CFIA or the Manufacturer has a "letter of no objection" from Health Canada. Water system design There are no cross connections between potable and non potable water supplies. Re-circulated water has a separate distribution system which is clearly identified. All hoses, taps and other similar sources of possible contamination are designed to prevent back flow or back siphonage. Where it is necessary to store water, storage facilities are adequately designed, constructed and maintained to prevent contamination (e.g., covered). Adverse water events The manufacturer has an action plan in the event of a boil water advisory/water safety alert. The action plan includes, but is not limited to disinfection or treatment of plant water, alternate water source, plant closure and an investigation into the safety of the product produced prior to the advisory. |
| Rating Guide | Examples |
| Rating I |
|
| Rating II |
|
| Rating III |
|
| Legal Authorities | PPR 14(1)(i) potable hot and cold water protected against contamination, adequate in quantity and pressure (2) Non potable may be used for fire protection, boilers or auxiliary services if there is no connection between system of non potable water and system of potable water 16 (9) Chemical agents properly used (12) Exposure to contamination |
| 4.1 | Premises |
|---|---|
| 4.1.4 | Water/Ice/Steam Quality |
| Task 4.1.4.2 | Steam |
| Task 302 | April 1, 2002 |
| Principle | The potability of steam in direct contact with food or food contact surfaces is controlled to prevent product contamination. |
| Assessment Criteria |
|
| Rating Guide | Examples |
| Rating I |
|
| Rating II |
|
| Rating III |
|
| Legal Authorities | PPR 16(15) Steam generated from potable water when used in the processing of a food (9) Chemical agents properly used (12) Exposure to contamination |
| 4.1 | Premises |
|---|---|
| 4.1.4 | Water/Ice/Steam Quality |
| Task 4.1.4.3 | Water/Ice/Steam Quality Records |
| Task 303 | January 31, 2008 |
| Principle | Written records that adequately reflect control of water, ice and steam quality and treatment are available upon request. |
| Assessment Criteria | The manufacturer has records available to demonstrate the adequacy of the microbiological and/or chemical safety of the water, ice and steam supply as follows: Water Potability Records
Water Treatment Records
Boiler Feedwater Treatment Records
Flume Water Treatment Records
Chiller Water Treatment Records
Ice Records
Adverse Water Event Records
|
| Rating Guide | Examples |
| Rating I |
|
| Rating II |
|
| Rating III |
|
| 4.2 | Transportation and Storage |
|---|---|
| 4.2.1 | Transportation |
| Task 4.2.1.1 | Food Carriers |
| Task 401 | April 1, 2002 |
| Principle | Carriers used by the manufacturer are designed, constructed, maintained, cleaned and utilized in a manner to prevent food contamination. |
| Assessment Criteria | The manufacturer verifies that carriers are suitable for the transportation of food. For example:
|
| Rating Guide | Examples |
| Rating I |
|
| Rating II |
|
| Rating III |
|
| 4.2 | Transportation and Storage |
|---|---|
| 4.2.1 | Transportation |
| Task 4.2.1.2 | Temperature Controls |
| Task 402 | April 1, 2002 |
| Principle | Ingredients and finished product requiring temperature controls are transported in a manner to prevent temperature abuse that could result in deterioration affecting product wholesomeness and safety. |
| Assessment Criteria |
|
| Rating Guide | Examples |
| Rating I |
|
| Rating II |
|
| Rating III |
|
| 4.2 | Transportation and Storage |
|---|---|
| 4.2.2 | Storage |
| Task 4.2.2.1 | Ingredients and Packaging Materials Storage |
| Task 501 | April 1, 2002 |
| Principle | Storage and handling of ingredients (incoming and in-process) and packaging materials is controlled to prevent damage and contamination. |
| Assessment Criteria |
|
| Rating Guide | Examples |
| Rating I |
|
| Rating II |
|
| Rating III |
|
| Legal Authorities | PPR 14(1)(p) Maintaining temperature and humidity 16(12) Exposure to a source of contamination (13) Temperature and humidity control |
| 4.2 | Transportation and Storage |
|---|---|
| 4.2.2 | Storage |
| Task 4.2.2.2 | Non Food Chemicals - Receiving and Storage |
| Task 502 | April 1, 2002 |
| Principle | Non-food chemicals are received and stored in a manner to prevent contamination of food, packaging materials and food contact surfaces. |
| Assessment Criteria |
|
| Rating Guide | Examples |
| Rating I |
|
| Rating II |
|
| Rating III |
|
| Legal Authorities | PPR 14(1)(g) Separation of incompatible operations 16(9) Chemical storage and labelling (12) Exposure to a source of contamination |
| 4.2 | Transportation and Storage |
|---|---|
| 4.2.3 | Storage |
| Task 4.2.2.3 | Finished Product Storage |
| Task 503 | January 31, 2008 |
| Principle | Finished products are stored and handled to prevent damage and contamination. |
| Assessment Criteria |
|
| Rating Guide | Examples |
| Rating I |
|
| Rating II |
|
| Rating III |
|
| Legal Authorities | PPR 14(1)(p) Maintaining temperature and humidity 16(12) Exposure to a source of contamination (14) Adversely affect colour or appearance |
| 4.2 | Transportation and Storage |
|---|---|
| 4.2.2 | Storage |
| Task 4.2.2.4 | Finished Product Storage - Frozen |
| Task 504 | April 1, 2002 |
| Principle | Frozen products are stored and handled to prevent damage, contamination and thawing. |
| Assessment Criteria |
|
| Rating Guide | Examples |
| Rating I |
|
| Rating II |
|
| Rating III |
|
| Legal Authorities | PPR 14(1)(p) Maintaining temperature and humidity 16(12) Exposure to a source of contamination (14) Adversely affect colour or appearance |
| 4.3 | Equipment |
|---|---|
| 4.3.1 | General Equipment |
| Task 4.3.1.1 | Design and Installation |
| Task 601 | April 1, 2002 |
| Principle | All equipment and utensils are designed, constructed and installed to function as intended, to permit effective cleaning and sanitation and to prevent contamination. |
| Assessment Criteria |
|
| Rating Guide | Examples |
| Rating I |
|
| Rating II |
|
| Rating III |
|
| Legal Authorities | PPR 14(1) (l) Equipment
16(11) Utensils identification and use |
| 4.3 | Equipment |
|---|---|
| 4.3.1 | General Equipment |
| Task 4.3.1.2 | Food Contact Surfaces |
| Task 602 | January 31, 2008 |
| Principle | Food contact surfaces are constructed of appropriate materials and are maintained in a manner to prevent contamination of food. |
| Assessment Criteria |
|
| Rating Guide | Examples |
| Rating I |
|
| Rating II |
|
| Rating III |
|
| Legal Authorities | PPR 14(1) m) Food contact surfaces are:
|
| 4.3 | Equipment |
|---|---|
| 4.3.1 | General Equipment |
| Task 4.3.1.3 | Equipment Maintenance and Calibration Program |
| Task 603 | January 31, 2008 |
| Principle | An effective maintenance and calibration program is in place to ensure that equipment performs consistently as intended and prevents contamination of product. |
| Assessment Criteria | Maintenance:
|
| Rating Guide | Examples |
| Rating I |
|
| Rating II |
|
| Rating III |
|
| Legal Authorities | PPR 30.2 c) Procedure for maintenance of thermal processing equipment |
| 4.3 | Equipment |
|---|---|
| 4.3.1 | General Equipment |
| Task 4.3.1.4 | Equipment Maintenance Records |
| Task 604 | April 1, 2002 |
| Principle | Records are available to demonstrate adherence to the maintenance program for critical equipment. |
| Assessment Criteria | The typical information expected in maintenance records for critical equipment:
|
| Rating Guide | Examples |
| Rating I |
|
| Rating II |
|
| Rating III |
|
| Legal Authorities | PPR 30.2 f) (iv) Maintenance Records of Thermal Processing Equipment (LACF only) |
| 4.3 | Equipment |
|---|---|
| 4.3.1 | General Equipment |
| Task 4.3.1.5 | Equipment Calibration Records |
| Task 605 | April 1, 2002 |
| Principle | Records are available to demonstrate adherence to the calibration/testing program of equipment/ instruments critical to food safety. |
| Assessment Criteria | Records are available to demonstrate that all equipment and instruments critical to food safety are calibrated or tested according to accepted frequency and procedures or according to manufacturer's specifications. Typical information expected in calibration records includes:
|
| Rating Guide | Examples |
| Rating I |
|
| Rating II |
|
| Rating III |
|
| Legal Authorities | PPR 30.2 f) (iv) Maintenance Records of Thermal Processing Equipment (LACF only) |
| 4.3 | Equipment |
|---|---|
| 4.3.2 | Pre-Process Equipment |
| Task 4.3.2.1 | Preparation/Blending Equipment and Instrumentation |
| Task 701 | April 1, 2002 |
| Principle | Preparation and blending equipment is designed, constructed, installed and maintained such that the equipment is capable of delivering the required process to ensure product safety. |
| Assessment Criteria | Equipment and instruments which control factors critical to product safety are designed, installed, constructed and calibrated as necessary to ensure that they function as intended. The following are some examples of instrumentation that may be required for preparation/blending equipment to control factors critical to the process: Mercury in Glass (MIG) Thermometers, Temperature Recorders, Other Temperature Measuring Devices.
Scales/Meters
Magnets
Metal Detectors
Other Instrumentation
|
| Rating Guide | Examples |
| Rating I |
|
| Rating II |
|
| Rating III |
|
| Legal Authorities | PPR 30.2 c) Maintenance Records of Thermal Processing Equipment (LACF only) |
| 4.3 | Equipment |
|---|---|
| 4.3.2 | Pre-Process Equipment |
| Task 4.3.2.2 | Filling Equipment and Instrumentation |
| Task 702 | April 1, 2002 |
| Principle | Filling equipment is designed, constructed, installed and maintained such that the equipment is capable of meeting the critical factors specified in the scheduled process. |
| Assessment Criteria | Filling equipment is designed, constructed, installed and maintained as necessary to provide the required fill weight/volume, the minimum initial temperature and to meet headspace/vacuum requirements. The following are some Examples of equipment that may be required for control of critical filling factors: MIG Thermometers, Temperature Recorders, Other Temperature Measuring Devices
Scales/Meters
Headspacers
|
| Rating Guide | Examples |
| Rating I |
|
| Rating II |
|
| Rating III |
|
| Legal Authorities | PPR 14 (1) l) Equipment
|
| 4.3 | Equipment |
|---|---|
| 4.3.2 | Pre-Process Equipment |
| Task 4.3.2.3 | Container Closure Equipment |
| Task 703 | April 1, 2002 |
| Principle | Container closure equipment is designed, constructed, installed and maintained such that the equipment is capable of hermetically sealing containers and, where necessary, providing the required vacuum. |
| Assessment Criteria |
Note: Anytime the equipment is delivering a defect included in the Metal Defect Manual it should be evaluated as either Minor or Serious. |
| Rating Guide | Examples |
| Rating I |
|
| Rating II |
|
| Rating III |
|
| Legal Authorities | PPR 14(1) l) Equipment 30.3 (c) LACF seamer maintenance |
| 4.3 | Equipment |
|---|---|
| 4.3.3 | Retort Equipment |
| Task 4.3.3.1 | Design, Installation and Maintenance (Still Steam Retort) |
| Task 801 | January 31, 2008 |
| Principle | Retort equipment is designed, constructed, installed and maintained to be capable of delivering the requirements of the thermal process. |
| Assessment Criteria | The retort system is designed, installed, constructed and maintained such that the equipment is capable of delivering the required process and controlling factors critical to thermal processing. Components of the system include: Steam Supply
Steam Controller
Steam Inlet
Steam Spreaders
Valves
Vents
Steam Traps
Bleeders
Mufflers
Water
Retort doors
Retort Structure
Crates, Baskets, Divider Plates
Preventative Maintenance Program
|
| Rating Guide | Examples |
| Rating I |
|
| Rating II |
|
| Rating III |
|
| Legal Authorities | PPR 14(1) l) Equipment 30.3 h) Maintenance of thermal processing equipment (LACF only) |
| 4.3 | Equipment |
|---|---|
| 4.3.3 | Retort Equipment |
| Task 4.3.3.2 | Retort Instrumentation |
| Task 802 | January 31, 2008 |
| Principle | Retort instrumentation is designed, installed, calibrated and maintained such that the instrumentation is capable of measuring, controlling and/or recording the critical factors in the thermal process. |
| Assessment Criteria |
Temperature Measuring Devices
MIG Thermometers
Temperature Recorders
Other Temperature Measuring Devices
Timing Devices
Pressure Gauges
Electronic Devices
|
| Rating Guide | Examples |
| Rating I |
NOTE: "under processing" would be evaluated in chapter 5 |
| Rating II |
|
| Rating III |
|
| Legal Authorities | PPR 14(1) l) Equipment 30.3 (i) Monitoring devices of thermal processing equipment (LACF only) |
| 4.3 | Equipment |
|---|---|
| 4.3.4 | Post-Process Equipment |
| Task 4.3.4.1 | Post-Process Cooling Canal and Handling Equipment |
| Task 901 | April 1, 2002 |
| Principle | Post-process cooling canal and handling equipment is designed, constructed, installed and maintained to prevent contamination and damage to containers. |
| Assessment Criteria |
|
| Rating Guide | Examples |
| Rating I |
|
| Rating II |
|
| Rating III |
|
| Legal Authorities | PPR 14(1)(l) Equipment
|
| 4.3 | Equipment |
|---|---|
| 4.3.4 | Post-Process Equipment |
| Task 4.3.4.1 | Low Vacuum Detection Equipment |
| Task 902 | April 1, 2002 |
| Principle | Low vacuum detection equipment is designed, installed, calibrated and maintained to eject containers with inadequate vacuum. |
| Assessment Criteria |
|
| Rating Guide | Examples |
| Rating I |
|
| Rating II |
|
| Rating III |
|
| Legal Authorities | PPR 14(1)(l) Equipment
|
| 4.4 | Personnel |
|---|---|
| 4.4.1 | Training |
| Task 4.4.1.1 | General Food Hygiene Training |
| Task 1001 | April 1, 2002 |
| Principle | Every food handler is trained in personal hygiene and hygienic handling of food such that they understand the precautions necessary to prevent the contamination of food. |
| Assessment Criteria | The manufacturer has a written training program for employees which is delivered as follows:
|
| Rating Guide | Examples |
| Rating I |
|
| Rating II |
|
| Rating III |
|
| Legal Authorities | PPR 16(12) Exposure to a source of contamination |
| 4.4 | Personnel |
|---|---|
| 4.4.1 | Training |
| Task 4.4.2.2 | Technical Training |
| Task 1002 | April 1, 2002 |
| Principle | Personnel are trained such that they have adequate technical knowledge and understanding of the operation(s) or process(es) for which they are responsible to ensure food safety. |
| Assessment Criteria | Training is appropriate to the complexity of the manufacturing process and the tasks assigned, e.g.:
|
| Rating Guide | Examples |
| Rating I |
|
| Rating II |
|
| Rating III |
|
| Legal Authorities | PPR 30.3(e) Certificate of competence in thermal processing |
| 4.4 | Personnel |
|---|---|
| 4.4.1 | Hygiene and Health Requirements |
| Task 4.4.2.1 | Cleanliness and Conduct |
| Task 1101 | April 1, 2002 |
| Principle | All persons entering food handling areas maintain an appropriate degree of personal cleanliness and take the appropriate precautions to prevent the contamination of food. |
| Assessment Criteria |
|
| Rating Guide | Examples |
| Rating I |
|
| Rating II |
|
| Rating III |
|
| Legal Authorities | PPR 16(4) Handwashing notices posted 17(2) Handwashing (3) Sanitary clothing, hair covering, impermeable gloves (4) Tobacco, chewing gum, food (5) Object that may contaminate the food |
| 4.4 | Personnel |
|---|---|
| 4.4.1 | Hygiene and Health Requirements |
| Task 4.4.2.2 | Communicable Diseases/Injuries |
| Task 1102 | April 1, 2002 |
| Principle | No person while known to be infected with a disease likely to be transmitted through food, or with open cuts or wounds, is permitted to work in food handling areas where there is a likelihood of such a person directly or indirectly contaminating the food. |
| Assessment Criteria |
|
| Rating Guide | Examples |
| Rating I |
|
| Rating II |
|
| Rating III |
|
| Legal Authorities | PPR 17(1) Communicable disease |
| 4.5 | Sanitation (and Pest Control) |
|---|---|
| 4.5.1 | Sanitation |
| Task 4.5.1.1 | Written Sanitation Program and Effectiveness Evaluation |
| Task 1201 | April 1, 2002 |
| Principle | An effective sanitation program for equipment and premises is in place to prevent contamination of food. |
| Assessment Criteria | The manufacturer has a written cleaning and sanitation program for all equipment which includes:
Procedures for cleaning and sanitizing as follows: Cleaned Out of Place Equipment (C.O.P., e.g., hand-cleaned)
Cleaned in Place Equipment (C.I.P)
The manufacturer has a written cleaning and sanitation program for premises (production and storage areas) which specifies areas to be cleaned, method of cleaning, person responsible and the frequency of the activity. Special sanitation and housekeeping procedures required during production are specified within the document, e.g., removal of product residues during breaks. Chemicals are used in accordance with the manufacturer's instructions and should be listed in the "Reference Listing of Accepted Construction, Packaging Materials and Non-Food Chemical Agents", published by CFIA or the manufacturer should have a "letter of no objection" from Health Canada. Cleaning and sanitizing equipment is designed for its intended use and is properly maintained. The sanitation program is carried out in a manner that does not contaminate food or packaging materials during or subsequent to cleaning and sanitizing, e.g., aerosols, chemical residues. Effectiveness of the sanitation program is monitored and verified (e.g., by routine inspection of premises and equipment and/or microbiological testing) and where necessary, the program is adjusted accordingly. Operations begin only after sanitation requirements have been met. |
| Rating Guide | Examples |
| Rating I |
|
| Rating II |
|
| Rating III |
|
| Legal Authorities | PPR 10(2) Sanitation program 16(1) Maintain sanitary conditions (2) Follow sanitation program (9) Label/store/use chemicals for sanitation (12) Exposure to contamination (14) Food Contact Surfaces |
| 4.5 | Sanitation (and Pest Control) |
|---|---|
| 4.5.1 | Sanitation |
| Task 4.5.1.2 | Equipment Cleanliness |
| Task 1202 | April 1, 2002 |
| Principle | The sanitation program is being followed so that the equipment and utensils are maintained in a sanitary condition that prevents contamination of food. |
| Assessment Criteria | The manufacturer maintains the equipment, utensils and other tools in a clean and sanitary manner:
|
| Rating Guide | Examples |
| Rating I |
|
| Rating II |
|
| Rating III |
|
| Legal Authorities | PPR 16(1) Maintenance of sanitary condition (2) Sanitation Program Followed (9) Handling and use of non food chemicals (12) Exposure to contamination (14) Food Contact Surfaces |
| 4.5 | Sanitation (and Pest Control) |
|---|---|
| 4.5.1 | Sanitation |
| Task 4.5.1.3 | Premises Cleanliness |
| Task 1203 | April 1, 2002 |
| Principle | The sanitation program is being followed so that the interior of the building and all other physical facilities are maintained in a sanitary and tidy condition that prevents contamination of food. |
| Assessment Criteria | The manufacturer maintains the building and physical facilities in a clean and sanitary manner.
|
| Rating Guide | Examples |
| Rating I |
|
| Rating II |
|
| Rating III |
|
| Legal Authorities | PPR 16(1) Maintenance of sanitary condition (2) Sanitation Program Followed (9) Handling and use of non-food chemicals (12) Exposure to contamination |
| 4.5 | Sanitation (and Pest Control) |
|---|---|
| 4.5.1 | Sanitation |
| Task 4.5.1.4 | Sanitation Records |
| Task 1204 | April 1, 2002 |
| Principle | Records are available to demonstrate the effectiveness of the sanitation program. |
| Assessment Criteria | The records of sanitation activities include the date, person responsible, the findings, corrective action taken, and microbiological test results where appropriate. |
| Rating Guide | Examples |
| Rating I |
|
| Rating II |
|
| Rating III |
|
| 4.5 | Sanitation (and Pest Control) |
|---|---|
| 4.5.1 | Pest Control |
| Task 4.5.2.1 | Pest Control Program |
| Task 1301 | April 1, 2002 |
| Principle | Effective pest control programs are in place to prevent entry, detect and eliminate pests and to prevent the contamination of food. |
| Assessment Criteria | There is an effective written pest control program for the premises and equipment that includes:
|
| Rating Guide | Examples |
| Rating I |
|
| Rating II |
|
| Rating III |
|
| Legal Authorities | PPR 16(8) Pest control Program |
| 4.5 | Sanitation (and Pest Control) |
|---|---|
| 4.5.1 | Pest Control |
| Task 4.5.2.2 | Pest Control Records |
| Task 1302 | April 1, 2002 |
| Principle | Records are available to demonstrate the effectiveness of the pest control program. |
| Assessment Criteria | Minimum pest control records include:
|
| Rating Guide | Examples |
| Rating I |
|
| Rating II |
|
| Rating III |
|
| 4.6 | Complaints and Recalls |
|---|---|
| 4.6.1 | Complaint Handling |
| Task 4.6.1.1 | Product Complaints |
| Task 1401 | April 1, 2002 |
| Principle | The establishment has an effective system for handling and investigating complaints. |
| Assessment Criteria | The manufacturer has a system to handle and investigate product complaints as follows:
|
| Rating Guide | Examples |
| Rating I |
|
| Rating II |
|
| Rating III |
|
| 4.6 | Complaints and Recalls |
|---|---|
| 4.6.1 | Complaint Handling |
| Task 4.6.1.2 | Complaint Records |
| Task 1402 | April 1, 2002 |
| Principle | Records of product complaints, investigation findings and action taken are available upon request. |
| Assessment Criteria | The establishment maintains or has access to detailed records of consumer complaints received, investigation, findings and corrective action taken. The minimum information required for complaint records related to Health and Safety Issues are as follows: Consumer Information
Investigation
|
| Rating Guide | Examples |
| Rating I |
|
| Rating II |
|
| Rating III |
|
| 4.6 | Complaints and Recalls |
|---|---|
| 4.6.1 | Recalls |
| Task 4.6.2.1 | Recall Plan |
| Task 1501 | April 1, 2002 |
| Principle | Every manufacturer of a food establishes a written recall plan to permit the complete, rapid recall of any lot of food from the market. |
| Assessment Criteria | The written recall plan includes:
Recall notification as follows:
|
| Rating Guide | Examples |
| Rating I |
|
| Rating II |
|
| Rating III |
|
| Legal Authorities | PPR 30.2 (d) written recall plan (LACF) only) (g) Notify the inspector of a recall (LACF only) 30.3 (d) Voding requirements (LACF only) |
| 4.6 | Complaints and Recalls |
|---|---|
| 4.6.1 | Recalls |
| Task 4.6.2.2 | Product Code Identification |
| Task 1502 | April 1, 2002 |
| Principle | Where required, each container of prepackaged food is identified with code marks or lot numbers marks either on the label or container as applicable. |
| Assessment Criteria | The coding requirements are different depending on the food types:
For low acid foods and acidified low acid foods:
For graded canned fruits:
For products prepared in a registered establishment which are packed for a first dealer under his private label:
For other food products
|
| Rating Guide | Examples |
| Rating I |
|
| Rating II |
|
| Rating III |
|
| Legal Authorities | PPR 30.3 d) coding requirements (LACF) 31 aa) Coding requirements for canned graded fruit and vegetables 33 Establishment identification on the label or the container when product is packed for a first dealer 46 e) Registration number of the packer on the external packages |
| 4.6 | Complaints and Recalls |
|---|---|
| 4.6.1 | Recalls |
| Task 4.6.2.3 | Recall Capability |
| Task 1503 | April 1, 2002 |
| Principle | Recall plans are tested periodically to verify the capability to rapidly identify and remove product from the market. |
| Assessment Criteria | The manufacturer is capable of producing accurate information on a timely basis to verify that all affected product can be rapidly identified and removed from the marketplace. This can be demonstrated by the manufacturer as follows:
|
| Rating Guide | Examples |
| Rating I |
|
| Rating II |
|
| Rating III |
|
| Legal Authorities | PPR 30.2 d) written recall plan (LACF only) g) Notify the inspector of a recall (LACF only) 30.3 d) Coding requirements (LACF only) |
| 4.6 | Complaints and Recalls |
|---|---|
| 4.6.1 | Recalls |
| Task 4.6.2.4 | Distribution Records |
| Task 1504 | April 1, 2002 |
| Principle | Product distribution records are available to enable the manufacturer to recall any lot of food. |
| Assessment Criteria | Distribution records contain sufficient information to permit traceability to a particular code or lot number. The following minimum information is required for distribution records:
|
| Rating Guide | Examples |
| Rating I |
|
| Rating II |
|
| Rating III |
|
| Legal Authorities | PPR 30.2(f) three year requirements for LACF (i) Volume, identification and distribution |
| 4.7 | Records |
|---|---|
| 4.7.1 | General Records |
| Task 4.7.1.1 | General Record Requirements |
| Task 1601 | April 1, 2002 |
| Principle | Information is recorded in a manner to represent an accurate history of the product or process. Records are retained for the required period of time. |
| Assessment Criteria | The following are requirements for all record keeping activities
|
| Rating Guide | Examples |
| Rating I |
|
| Rating II |
|
| Rating III |
|
| 4.7 | Records |
|---|---|
| 4.7.1 | General Records |
| Task 4.7.1.1 | General Regulatory Requirements |
| Task 1602 | April 1, 2002 |
| Principle | Current Certificate of Registration is posted in a conspicuous place in the establishment for the period during which the certificate remains in force. |
| Assessment Criteria |
|
| Rating Guide | Examples |
| Rating I |
|
| Rating II |
|
| Rating III |
|
| Legal Authorities | PPR 11(2) Certificate of registration posted |
Next Page: Chapter 5 | Previous: Chapter 3